The Hygienic Mix Proof Tank Outlet Valve N5 is the Tank Bottom Seat version of our Mix Proof Valves. It is available with one or two ports as well as with a lose or a machined weld-in flange. For horizontal build in positions we recommend the version N52 (see body types).
Material | in contact with product optional not in contact with product |
1.4404/AISI316L 1.4435/AISI316L 1.4301/AISI304 |
|
Gaskets | O-rings/gaskets | EPDM (others on request) |
|
Temperatures |
maximum | EPDM | |
continuous operation
sterilisation temperature |
130 °C* 150 °C* short-time (approx. 20 min) |
||
Pressures | closing pressure
air pressure |
max. 4 bar in the Tank max. 10 bar in the Pipe min 6 bar – |
|
Surfaces |
in contact with product optional not in contact with product |
Ra ≤ 0,8 µm e-polished, other surfaces on request Ra ≤ 1,6 µm |
|
Connections Standard- pipe classes |
DIN 11850-R2 (DIN 11866 A) O.D.-Tube (DIN 11866 C) |
This control top has been developed between AWH and Rieger in collaboration with Bürkert. It serves as a custom-fit solution for our in-house hygienic and aseptic process valves to achieve an even more efficient and precise application.
Contact-free inductive valve position measuring (Teach function)
FlowStar is available in the models 24 V DC, AS-I bus, IO-Link (Port Class A) or Ethernet IP.
All models are available as the following alternative:
Mounting kit integrated in Control Top – no separate mounting kit necessary. Exception for LCV valves, ESV valves.
All Valves are available in special alloys, such as Hastelloy® C-22, 1.4539/904L, 1.4529, AL-6XN® and others.
Directly send us your inquiry:
sales@rr-rieger.de
Tel.: +49 7361 5702-0