The patented RIEGER aseptic double-seat valve N13 incorporates the technologies of hygienic and aseptic valve design in one valve.
It combines the advantages of the long-proven hygienic double-seat valve N1 with those of the aseptic double-seat valve N7. You could also call it a hybrid double-seat valve.
The bellows seal hermetically to the surroundings. The double valve seat reliably separates the two process rails from each other to prevent unwanted mixing of two liquids.
The special feature of the valve eliminates the need for CIP/SIP valves, the leakage chamber and enables a very compact valve.
This valve replaces the double-seat valves with stem flushing known on the market, eliminating the costs for sealing media and their control.
Material | product touched optional not in contact with the product |
1.4404/AISI316L 1.4435/AISI316L 1.4301/AISI304 |
|
Seals | Teflon bellows Metal bellows O-rings/seals |
PTFE 1.4571/1.4404 EPDM |
|
Temperatures | maximum | EPDM | PTFE |
Continuous operating temperature
Sterilization temperature |
130 °C*
150 °C* |
121 °C*
135 °C* short term |
|
Press | Closing pressure
Control air pressure |
max. 6 bar
min. 6 bar – |
|
Surfaces | product touched optional not in contact with the product |
Ra ≤ 0.8 µm e-polished, other surfaces on request Ra ≤1.6 µm |
|
Connections Standard Pipe classes |
DIN 11850-R2 (DIN 11866 A) O.D. tube (DIN 11866 C) DIN EN ISO 1127 (DIN 11866-B) |
Structure of the valve | Solid valve body
No dead spaces completely idle Many installation positions possible |
Absolute product protection | Complete separation from the environment
no swamp, no cathedral |
Service friendliness | Gasket replacement without special tools
Short downtimes Screwed bellows Optimal to clean |
Economic efficiency | Long service life of the PTFE bellows
Standard gaskets Minimal maintenance costs |
The Rieger control head was developed in collaboration between AWH and Rieger together with Bürkert.
Rieger thus offers you a tailor-made solution for your in-house hygienic and aseptic process valves so that they can be used even more efficiently and accurately.
NON-CONTACT INDUCTIVE VALVE POSITION DETECTION (TEACH FUNCTION)
The FlowStar is available in 24 V DC, AS-I bus, IO-Link (Port Class A) or Ethernet IP versions.
All versions are available as the following alternative:
Mounting kit integrated in the control head – no separate mounting kit required. Exception for LCV valves, ESV valves.
All valves are available in special materials such as Hastelloy® C-22, 1.4539/904L, 1.4529, AL-6XN® and others .
Please contact us directly:
sales@rr-rieger.de