Search

Sampling valves BioCheck Classic DN15 DIN

With the BioCheck sampling valve, samples can be taken easily and safely from closed systems such as containers and pipelines.
When designing this sterile valve, particular emphasis was placed on the aseptic but also very compact design, so that it can be integrated into both sterile and CIP/SIP circuits without any problems and, above all, without contamination.

BioCheck sampling valves are certified according to TA-Luft / VDI 2440 / VDI 3479

All enclosures are also available with just 1 outlet.
Weld ends are the standard design for all enclosure shapes, but other connections are available on request.

The BioCheck sampling valve DN15 DIN is

/ for highly viscous media

/ available as standard version

Special variants from DN20 to DN40 available on request.

Material in contact with the product
optional

not in contact with the product

1.4404/AISI316L
1.4435/AISI316L
Hastelloy® C-22 and others
1.4301/AISI304
Seals Teflon bellows PTFE
Temperatures maximum PTFE
Continuous operating temperature

Sterilization temperature

121 °C*

135 °C* for a short time
(approx. 20 min)

Press Closing pressure

Control air pressure

max. 10 bar
(more on request)

min 6 bar –
max. 10 bar

Surfaces in contact with the product
optional

not in contact with the product

Ra ≤ 0.8 µm
e-polished, other surfaces on request
Ra ≤ 1.6 µm
Connections
Standard-
Pipe classes
DIN 11850-R2 (DIN 11866 A)
O.D.-Tube (DIN 11866 C)
Executions S = self-closing hand lever
O = hand lever for open position
P = with holder for initiator dm 12 mm
H = manual override with handwheel
Stroke DN 15 DIN = 4.5 mm
*dependent on operating parameters