The RIEGER Safety valve Type SH prevents excessive pressure in steam and gaseous media in plant components and tanks. The set pressure is generally higher than the operating pressure of the system.
Already at 10% overpressure valve opens with full stroke.
The pharmaceutical and chemical industries as well as the biotechnology, like the cosmetics, food and beverage industry, are the ideal applications for the RIEGER safety valve.
Operating variants:
Material | in contact with product optional not in contact with product |
1.4404/AISI316L 1.4435/AISI316L 1.4301/AISI304 |
|
Gaskets | O-rings/gaskets | EPDM (others on request) |
|
Temperatures | EPDM | ||
maximum continuous operation steam sterilization |
130 °C* 150 °C* short-time (approx. 20 min) |
||
Pressures | closing pressure
air pressure |
from1,5 bar – 8 bar
min 6 bar – |
|
Surfaces | in contact with product optional not in contact with product |
Ra ≤ 0,8 µm e-polished, other surfaces on request Ra ≤ 1,6 µm |
|
Connections Standard-pipe classes |
DIN 11850-R2 (DIN 11866 A) O.D.-Tube (DIN 11866 C) |
DN 10 – DN 50
Feedback can be provided via special magnetic field sensors from outside through the casing, this must be communicated before ordering.
Directly send us your inquiry:
sales@rr-rieger.de
Tel.: +49 7361 5702-0
All valves are available in special materials such as Hastelloy® C-22, 1.4539/904L, 1.4529, AL-6XN® and others .
Please contact us directly:
sales@rr-rieger.de
Phone: +49 7361 5702-0