Search

SHF hygienic safety valves

The RIEGER safety valve type SHF prevents impermissible excess pressure for vaporous and gaseous media in system components and tanks. The set pressure is generally greater than the operating pressure of the system.

The valve opens with full stroke as soon as the pressure exceeds 10 %.

The pharmaceutical, chemical and biotechnology industries as well as the cosmetics, beverage and food industries are the ideal areas of application for the RIEGER safety valve.

To the Dekra certificate

Materialin contact with the product
optional
not in contact with the product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
SealsO-rings/sealsEPDM
(others on request)
TemperaturesmaximumEPDM
Continuous operating temperature
Sterilization
temperature
130 °C*

150 °C*
short term (approx. 20 min.)

Press Closing pressure

Control air pressure

from 1.5 bar – 8 bar

min 6 bar –
max. 10 bar

Surfaces product touched
optional

not in contact with the product

Ra ≤ 0.8 µm
e-polished, other surfaces on request
Ra ≤ 1.6 µm
Connections
Standard-
Pipe classes
DIN 11850-R2 (DIN 11866 A)
O.D.-Tube (DIN 11866 C)
*dependent on operating parameters

Login bei Rieger

Login at Rieger

Bei Rieger registrieren

Register with Rieger