Hygienic Safety Valves SH

The RIEGER Safety valve Type SH prevents excessive pressure in steam and gaseous media in plant components and tanks. The set pressure is generally higher than the operating pressure of the system.

Already at 10% overpressure valve opens with full stroke.

The pharmaceutical and chemical industries as well as the biotechnology, like the cosmetics, food and beverage industry, are the ideal applications for the RIEGER safety valve.

Operating variants:

  • pneumatically liftable
  • liftable with lever
  • pneumatically liftable with additional lever

Click here for the certificate.

Material in contact with product
optional
not in contact with product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
Gaskets O-rings/gaskets EPDM
(others on request)
Temperatures EPDM
maximum
continuous operation
steam sterilization
130 °C*
150 °C*
short-time
(approx. 20 min)
Pressures closing pressure

air pressure

from1,5 bar – 8 bar

min 6 bar –
max. 10 bar

Surfaces in contact with product
optional

not in contact with product

Ra ≤ 0,8 µm
e-polished,
other surfaces
on request
Ra ≤ 1,6 µm
Connections
Standard-pipe classes

DIN 11850-R2 (DIN 11866 A)
O.D.-Tube (DIN 11866 C)
                                                                                 *dependent upon operating conditions