Search

Hygienic overflow valves type ÜS

RIEGER Overflow valves ÜS open the set response and thus prevent unwanted pressures in pipelines. They are available with weld ends and with dairy screwings or clamp ferrules. One possible application is the protection of forced-feed pumpsperistaltic pumps.

The overflow valve US is suitable for all liquid media.

Overflow valves are no safety valves.
For this purpose we recommend the TÜV certified safety valve type SH.

Material in contact with product
optional
not in contact with product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
Gaskets
O-rings/gaskets EPDM, FKM
(others on request)
Temperatures maximum EPDM
continuous operation

steam sterilization

130 °C*

150 °C* short-time
(approx. 20 min.)

Set range
In order set pressure point is requested, pressure spring is
chosen accordingly.
0,5 bar – 6 bar

higher set pressures upon request

Set pressure range
of pressure spring
according to customer’s request in lower
or upper pressure range
Surfaces
in contact with product
optional

not in contact with product

Ra ≤ 0,8 µm
e-polished, other surfaces on request

Ra ≤ 1,6 µm

Connections
Standard-
pipe classes
DIN 11850-R2 (DIN 11866 A)
O.D. tube (DIN 11866 C)
clamp ferrules in DIN and Inch
                                                                                 *dependent upon operating conditions

Login bei Rieger

Login at Rieger

Bei Rieger registrieren

Register with Rieger