Search

Hygiene overflow valves type ER

The Rieger type ER overflow valves have evolved from the type E8 and form the “Reverse Acting” series of Rieger overflow valves. These type ER overflow valves can be opened pneumatically for CIP cleaning. You can also change the setting pressure manually within the available setting range. This type of valve with its housing configuration is used to protect a pump with a bypass line.

Material product touched
optional
not in contact with the product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
Seals O-rings/seals EPDM
(others on request)
Temperatures maximum EPDM
Continuous operating temperature

Sterilizing
temperature

130 °C*

150 °C* short term
(approx. 20 min)

Press Possible set pressure with O-ring design 0.5 – 10 bar (higher pressures on request)
Pressure range depending on installed spring Specify desired setting pressure when ordering
Control air pressure min. 6 bar –
max. 10 bar
Surfaces product touched
optional

not in contact with the product

Ra ≤ 0.8 µm
e-polished, other surfaces on request
Ra ≤ 1.6 µm
Connections
Standard
Pipe classes
DIN 11850-R2 (DIN 11866 A)
O.D. tube (DIN 11866 C)
DIN EN ISO 1127 (DIN 11866-B)

 

*dependent on operating parameters