Search

Aseptic overflow valves E8

RIEGER E8 overflow valves are a combination of angle valves and overflow valves. Unlike an overflow valve, this valve opens with up to 100 % stroke like an angle valve if required. It is possible to seal the overflow valves.

One possible application is the protection of forced feed pumps (e.g. peristaltic pumps).

The E8 overflow valve is suitable for all liquid media.

Overflow valves are not safety valves.
We recommend the TÜV-certified safety valve type SH for this purpose.

Material product touched
optional
not in contact with the product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
Seals Teflon bellows
O-rings/seals
PTFE
EPDM
(others on request)
Temperatures maximum EPDM PTFE
Continuous operating temperature

Sterilizing
temperature

130 °C*

150 °C*

121 °C*

135 °C* short term
(approx. 20 min)

Press Possible set pressure with O-ring design 0.5 – 10 bar (higher pressures on request)
PTFE bellows design

Pressure range depending on installed spring

2 – 6 bar

Specify desired setting pressure when ordering

Control air pressure min. 6 bar – max. 10 bar
Surfaces product touched
optional

not in contact with the product

Ra ≤ 0.8 µm
e-polished, other surfaces on request
Ra ≤ 1.6 µm
Connections
Standard
Pipe classes
DIN 11850-R2 (DIN 11866 A)
O.D. tube (DIN 11866 C)
DIN EN ISO 1127 (DIN 11866-B)

 

*dependent on operating parameters

Login bei Rieger

Login at Rieger

Bei Rieger registrieren

Register with Rieger