With the BioCheck sampling valve, samples can be taken easily and safely from closed systems such as containers and pipes.
When constructing this sterile fitting, particular emphasis was placed on the aseptic but also very compact design, so that it can be integrated into both sterile and CIP/SIP circuits without any problems and, above all, without contamination.
BioCheck sampling valves are certified according to TA-Luft / VDI 2440 / VDI 3479
All enclosures are also available with only 1 outlet.
Weld ends are the standard design for all housing types, but other connections are available on request.
Material | product touched optional not in contact with the product |
1.4404/AISI316L 1.4435/AISI316L Hastelloy® C-22 and others 1.4301/AISI304 |
|
Seals | Teflon bellows | PTFE | |
Temperatures | maximum | PTFE | |
Continuous operating temperature
Sterilization temperature |
121 °C*
135 °C* short term |
||
Press | Closing pressure
Control air pressure |
max. 10 bar (more on request) min 6 bar – |
|
Surfaces | product touched optional not in contact with the product |
Ra ≤ 0.8 µm e-polished, other surfaces on request Ra ≤ 1.6 µm |
|
Connections Standard Pipe classes |
DIN 11850-R2 (DIN 11866 A) O.D. tube (DIN 11866 C) |
||
Executions | S = self-closing hand lever O = Hand lever for open position P = with holder for initiator dm 12 mm H = Manual operation with handwheel |
||
Stroke | Standard DN 10 DIN = 3 mm DN 15 DIN = 4.5 mm Ingold version = 5 mm |
All valves are available in special materials such as Hastelloy® C-22, 1.4539/904L, 1.4529, AL-6XN® and others .
Please contact us directly:
sales@rr-rieger.de
Phone: +49 7361 5702-0