Hygienic Safety Valves SH

The RIEGER Safety valve Type SH prevents excessive pressure in steam and gaseous media in plant components and tanks. The set pressure is generally higher than the operating pressure of the system.
 
Already at 10% overpressure valve opens with full stroke.

The pharmaceutical and chemical industries as well as the biotechnology, like the cosmetics, food and beverage industry, are the ideal applications for the RIEGER safety valve.


Operating variants:

  • pneumatically liftable
  • liftable with lever
  • pneumatically liftable with additional lever


For certificate click here




Materialin contact with product
optional
not in contact with product
1.4404/AISI316L
1.4435/AISI316L
1.4301/AISI304
   
GasketsO-rings/gaskets
 
EPDM
(others on request)
   
Temperatures


 EPDM
 

maximum
continuous operation
steam sterilization



130 °C*
150 °C*
short-time
(approx. 20 min)

    
Pressuresclosing pressure

air pressure
 
from1,5 bar - 8 bar
 
min 6 bar -
max. 10 bar
   
Surfacesin contact with product
optional


not in contact with product
Ra ≤ 0,8 µm
e-polished,
other surfaces
on request
Ra ≤ 1,6 µm
   
Connections
Standard-pipe classes

DIN 11850-R2 (DIN 11866 A)
O.D.-Tube (DIN 11866 C)
 
                                                                                 *dependent upon operating conditions

DN 10 - DN 50


  • TÜV approval for steam and gases
  • no dead spaces, no swamp, no dome
  • one-piece solid valve housing
  • inlet is always smaller than outlet
  • seal replacement without special tools
Feedback can be provided via special magnetic field sensors from outside through the casing, this must be communicated before ordering.

Directly send us your inquiry:
sales@rr-rieger.de
Tel.: +49 7361 5702-0
All Valves are available in special alloys, such as Hastelloy® C-22, 1.4539/904L, 1.4529, AL-6XN® and others.

Directly send us your inquiry:
sales@rr-rieger.de
Tel.: +49 7361 5702-0
LET US ADVISE YOU