{"id":5184,"date":"2024-03-23T17:12:12","date_gmt":"2024-03-23T16:12:12","guid":{"rendered":"https:\/\/rr-rieger.com\/ventile\/hygiene-shut-off-valves-esv\/"},"modified":"2025-12-22T14:44:50","modified_gmt":"2025-12-22T13:44:50","slug":"hygiene-absperrventile-esv","status":"publish","type":"ventile","link":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/","title":{"rendered":"Hygiene shut-off valves ESV"},"template":"","meta":{"product_description":"<p>RIEGER ESV hygienic single-seat valves are used whenever maximum productivity, safety and quality are required. They can be found in plants in the dairy industry, the food industry, the pharmaceutical and chemical industries and biotechnology.<\/p>\n<p>The advanced valve concept, proven a thousand times over in daily use, guarantees a high degree of flexibility within the individual series. RIEGER ESV hygienic single-seat valves guarantee our customers the perfect problem solution for their liquid products.<\/p>\n<p>Thanks to the modular system, the conversion from hygienic to aseptic design, from \"air-opening\" to \"air-closing\" is possible without any problems. The dimensions can also be adapted to the conditions on site.<\/p>\n","technical_data":"<table border=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td><strong>Material<\/strong><\/td>\n<td colspan=\"2\">in contact with the product<br>optional<br>not in contact with the product<\/td>\n<td>1.4404\/AISI316L<br>1.4435\/AISI316L<br>1.4301\/AISI304<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Seals<\/strong><\/td>\n<td colspan=\"2\">O-rings\/seals<\/td>\n<td>EPDM<br>(others on request)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Temperatures<\/strong><\/td>\n<td colspan=\"2\" rowspan=\"1\">maximum<\/td>\n<td>EPDM<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\" rowspan=\"1\">Continuous operating temperature<\/p>\n<p>Sterilization temperature<\/td>\n<td>130 \u00b0C*<\/p>\n<p>150 \u00b0C* for a short time<br>(approx. 20 min)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Press<\/strong><\/td>\n<td colspan=\"2\">Closing pressure<\/p>\n<p>Control air pressure<\/td>\n<td>max. 6 bar<\/p>\n<p>min 6 bar -<br>max. 10 bar<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Surfaces<\/strong><\/td>\n<td colspan=\"2\">in contact with the product<br>optional<\/p>\n<p>not in contact with the product<\/td>\n<td>Ra \u2264 0.8 \u00b5m<br>e-polished, other surfaces on request<br>Ra \u2264 1.6 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Connections<br>Standard-<br>Pipe classes<\/strong><\/td>\n<td colspan=\"3\">DIN 11850-R2 (DIN 11866 A)<br>O.D.-Tube (DIN 11866 C)<br>DIN EN ISO 1127 (DIN 11866-B)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<div align=\"center\">  *dependent on operating parameters<\/div>\n","benefits":"<table border=\"0\" cellpadding=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td valign=\"TOP\"><strong>Absolute product protection<br><\/strong><\/td>\n<td>Technically vacuum-safe<\/p>\n<p>Securely chambered profile seal on the spindle of the hygienic single-seat valves<br>fulfills the functions of a wiper and a seal<\/p>\n<p>Axial sealing with O-rings in the valve seat<\/p>\n<p>No migration behind the O-rings due to unique O-ring groove<\/p>\n<p>No screw connections in the product chamber thanks to one-piece valve discs<\/p>\n<p>\u00a0<\/td>\n<\/tr>\n<tr>\n<td valign=\"TOP\"><b>Service friendliness<\/b><\/td>\n<td>\u00a0<\/p>\n<p>Gasket replacement without special tools<\/p>\n<p>Drives completely maintainable<\/p>\n<p>Actuators can be converted from spring-closing to spring-opening and vice versa<\/p>\n<p>Low control air requirement<\/p>\n<p>Valve insert can be removed upwards<\/p>\n<p>\u00a0<\/td>\n<\/tr>\n<tr>\n<td valign=\"TOP\"><b>Economic efficiency<\/b><\/td>\n<td>Upgrade to aseptic version possible<\/p>\n<p>Low pressure loss<\/p>\n<p>Spherical housing prevents dome and sump in the valve<\/p>\n<p>Full-stroke design shortens cleaning time with viscous media<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","electronic_feedback":"<p><img class=\"alignnone size-medium wp-image-970\" src=\"https:\/\/rr-rieger.com\/wp-content\/uploads\/2024\/03\/rr-rieger-flowstar-logo-300x84.png\" alt=\"\" width=\"300\" height=\"84\"><\/p>\n<p><b>The control head from Rieger was developed in collaboration between AWH and Rieger together with B\u00fcrkert.<br>Rieger thus offers you a tailor-made solution for your in-house hygienic and aseptic process valves, enabling them to be used even more efficiently and accurately.<\/b><\/p>\n<p><b>NON-CONTACT INDUCTIVE VALVE POSITION DETECTION (TEACH FUNCTION)<\/b><\/p>\n<ul>\n<li>Colored illuminated status display<\/li>\n<li>Integrated control air routing in the drive<\/li>\n<li>Fieldbus interface AS-Interface, DeviceNet, IO-Link or B\u00fcrkert system bus (b\u00fcS)<\/li>\n<li>with ATEX option:<br>Ex II 3 G Ex ec IIC T4 Gc X<br>Ex II 3 D Ex tc IIIC T135\u00b0C Dc X<\/li>\n<\/ul>\n<p>The FlowStar is available in 24 V DC, AS-I bus, IO-Link (Port Class A) or Ethernet IP versions.<br>All versions are available as the following alternatives:<\/p>\n<ul>\n<li>without solenoid valve, 3 internal switching points + 1 output for ext. Switching point via Ini<\/li>\n<li>1 solenoid valve, 3 internal switching points + 1 output for ext. Switching point via Ini<\/li>\n<li>2 solenoid valves, 3 internal switching points + 1 output for ext. Switching point via Ini<\/li>\n<\/ul>\n<p>Mounting kit integrated in the control head - no separate mounting kit required. Exception for LCV valves, ESV valves.<\/p>\n","special_alloys":"<p>All valves are available in special materials such as <b>Hastelloy\u00ae C-22, 1.4539\/904L, 1.4529, AL-6XN\u00ae <\/b>and <b>others <\/b>.<\/p>\n<p>Please contact us directly:<br><a href=\"mailto:sales@rr-rieger.de\">sales@rr-rieger.de<\/a><br>Tel.: +49 7361 5702-0<\/p>\n","image":"1492","valve_category":"hygienic_valves"},"class_list":["post-5184","ventile","type-ventile","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Hygiene shut-off valves ESV | Rieger<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hygiene shut-off valves ESV | Rieger\" \/>\n<meta property=\"og:url\" content=\"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/\" \/>\n<meta property=\"og:site_name\" content=\"Rieger\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-22T13:44:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/rr-rieger.com\/wp-content\/uploads\/2024\/04\/ventilknoten-2.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"266\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/hygiene-absperrventile-esv\\\/\",\"url\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/hygiene-absperrventile-esv\\\/\",\"name\":\"Hygiene shut-off valves ESV | Rieger\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#website\"},\"datePublished\":\"2024-03-23T16:12:12+00:00\",\"dateModified\":\"2025-12-22T13:44:50+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/hygiene-absperrventile-esv\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/hygiene-absperrventile-esv\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/hygiene-absperrventile-esv\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ventile\",\"item\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/valves\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Hygiene shut-off valves ESV\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/\",\"name\":\"Rieger\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#organization\",\"name\":\"Gebr. Rieger GmbH + Co. KG\",\"alternateName\":\"Rieger Ventile\",\"url\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/rr-rieger.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Rieger_Logo_rgb.svg\",\"contentUrl\":\"https:\\\/\\\/rr-rieger.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Rieger_Logo_rgb.svg\",\"width\":321,\"height\":148,\"caption\":\"Gebr. Rieger GmbH + Co. KG\"},\"image\":{\"@id\":\"https:\\\/\\\/rr-rieger.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/gebr-rieger-gmbh-co-kg\",\"https:\\\/\\\/www.xing.com\\\/pages\\\/gebr-riegergmbh-co-kg\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCqQFMV0rzMqaov3sR3nNBqw\",\"https:\\\/\\\/vimeo.com\\\/gebrrieger\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hygiene shut-off valves ESV | Rieger","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/","og_locale":"en_US","og_type":"article","og_title":"Hygiene shut-off valves ESV | Rieger","og_url":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/","og_site_name":"Rieger","article_modified_time":"2025-12-22T13:44:50+00:00","og_image":[{"width":400,"height":266,"url":"https:\/\/rr-rieger.com\/wp-content\/uploads\/2024\/04\/ventilknoten-2.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/","url":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/","name":"Hygiene shut-off valves ESV | Rieger","isPartOf":{"@id":"https:\/\/rr-rieger.com\/en\/#website"},"datePublished":"2024-03-23T16:12:12+00:00","dateModified":"2025-12-22T13:44:50+00:00","breadcrumb":{"@id":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/rr-rieger.com\/en\/valves\/hygiene-absperrventile-esv\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/rr-rieger.com\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Ventile","item":"https:\/\/rr-rieger.com\/en\/valves\/"},{"@type":"ListItem","position":3,"name":"Hygiene shut-off valves ESV"}]},{"@type":"WebSite","@id":"https:\/\/rr-rieger.com\/en\/#website","url":"https:\/\/rr-rieger.com\/en\/","name":"Rieger","description":"","publisher":{"@id":"https:\/\/rr-rieger.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/rr-rieger.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/rr-rieger.com\/en\/#organization","name":"Gebr. Rieger GmbH + Co. KG","alternateName":"Rieger Ventile","url":"https:\/\/rr-rieger.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/rr-rieger.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/rr-rieger.com\/wp-content\/uploads\/2024\/02\/Rieger_Logo_rgb.svg","contentUrl":"https:\/\/rr-rieger.com\/wp-content\/uploads\/2024\/02\/Rieger_Logo_rgb.svg","width":321,"height":148,"caption":"Gebr. Rieger GmbH + Co. KG"},"image":{"@id":"https:\/\/rr-rieger.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/gebr-rieger-gmbh-co-kg","https:\/\/www.xing.com\/pages\/gebr-riegergmbh-co-kg","https:\/\/www.youtube.com\/channel\/UCqQFMV0rzMqaov3sR3nNBqw","https:\/\/vimeo.com\/gebrrieger"]}]}},"_links":{"self":[{"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/ventile\/5184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/ventile"}],"about":[{"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/types\/ventile"}],"version-history":[{"count":2,"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/ventile\/5184\/revisions"}],"predecessor-version":[{"id":8926,"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/ventile\/5184\/revisions\/8926"}],"wp:attachment":[{"href":"https:\/\/rr-rieger.com\/en\/wp-json\/wp\/v2\/media?parent=5184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}